Introducing the new PV monitoring package designed to work with an SMA cluster controller. The package includes a silicon-cell pyranometer with a mounting bracket, Class A PRT back-of-panel temperature sensor with Kapton tape, fan-aspirated solar radiation shield with 24 V-12 V DC converter, and Class A PRT air temperature sensor with TS-100 port adapter.
Fan-Aspirated Solar Radiation Shield (TS-100)
- 防止太阳辐射引起的错误
- Long life, IP55 rated fan
- Meets IEC 61724-1 requirements
有关可用TS-100的更多信息这里.
- 包括24 V-12 V DC Converter
We are currently looking for case studies for this product. If you would like to share your application of this product, please点击这里.
当前库存:
SP-214 Silicon-cell Pyranometer
规范s
电源
5至36 V DC,最大电流漏极22 mA(2 mA静态电流漏极)
Sensitivity
0.013 mA per W mˉ²
Calibration Factor
78 W mˉ² mA (reciprocal of sensitivity) with an offset of 4.0 mA
Calibration Uncertainty
± 5 %
校准输出范围
4到20 mA
Measurement Repeatablitiy
Less than 1 %
Non-stability (Long-term Drift)
Less than 2 % per year
Non-linearity
Less than 1 % (up to 1250 W mˉ², maximum radiation measurement is 1250 w mˉ²)
Response Time
Less than 1 ms
视野
180岁
光谱范围
360 to 1120 nm (wavelengths where response is 10 % of maximum)
定向(余弦)响应
±5%在75°˚天顶角
Temperature Response
0.04 ± 0.04 % per C
Operating Environment
-40 to 70 C, 0 to 100 % relative humdiity, can be submerged in water up to depths of 30 m
Dimensions
24 mm diameter, 28 mm height
电缆
5 m of shielded, twisted-pair wire with santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions)
Mass
140克(带5米的铅线)
Warranty
4 years against defects in materials and workmanship
CS240 Back-of-Pannel Temperature Sensor
规范s
Element Type
Precision 1000 Ω class A platinum sensing element
Tolerance
± (0.15 + 0.002t)
温度系数
TCR = 3850 ppm/K
Long-Term Stability
Maximum R₀ drift 0.04 % (after 1000 h at 400 C)
Measuring Current
0.1 to 0.3 mA
Operating Tempertature Range
-40到105 c
Disk Material
Anodized aluminum
电缆Jacket Material
黑色半光泽PVC,UL VWI阳光抗性户外用途
Disk Diameter
25.4毫米
Overall Probe Length
63.5毫米
Overmolded Joint Dimensions
57.2 x 11.2 x 14.7 mm
ST-150 Class A PRT
规范s
测量范围
-50 to 70 C
测量的不确定性
0.3 C (-40 to 60 C), Class A
Measurement Repeatability
Less than 0.01 C
Long-term Drift
Less than 0.05 C per year
Equilibration Time
15 seconds
自加热
Less than 0.01 C (typical, assuming pulsed excitation of 2.1 V DC), 0.09 at 5 C (max. assuming continuous input excitation of 2.1 V DC)
Operating Environmental
-50 to 70 C, 0 to 100 % relative humidity
Input Voltage Requirement
Datalogger依赖
Output Voltage Requirement
Datalogger依赖
电流消耗
Datalogger依赖
Dimensions
56 mm, 3 mm diameter
Mass
95 g
Warranty
4 years against defects in materials and workmanship
TS-100 Fan-Aspirated Radiation Shield
规范s
Difference among Individual Replicate Shields
Less than 0.1 C
Aspiration Rate
6 m sˉ¹ at full-speed, 3 m sˉ¹ at half-speed
Fan Input Voltage Requirement
10.8 to 13.2 V DC
风扇电流消耗
全速80 mA,半速以25 mA
风扇灰尘和防水
IP55
Dimensions
220 mm height, 270 mm diameter
Mass
840 g
电缆s
5米屏蔽,双绞线电线适用于风扇和空气温度传感器,具有Santoprene橡胶夹套(高耐水性,高紫外线稳定性,寒冷条件的柔韧性),尾纤铅线
Warranty
4 years against defects in materials and workmanship